top of page

Reverse Osmosis Water System

AQUASKY  ROT-4

-  SHOP WITH US  -

Systems

YOU HAVE ONLY ONE BODY AND ONE LIFE

Aqua Sky Reverse Osmosis 5 stage  -  pa-e reverse osmosis replacement cartridges

 reverse osmosis , replacement , repair , service

Call 1-800-551-3221

    Aqua Sky Reverse Osmosis

    Higher Performance RO membranes

    aqua Sky Water Plant ,  known as Hyper-filtration by the industry, represents state-of-the-art in water treatment technology. it was developed in the late 1950's under U.S. Government funding, as a method of desalinating sea water. Today, it has earned its name as the most convenient and thorough method to filter water. It is used by most water bottling plants, and by many industries that require ultra-refined water in manufacturing. Now this advanced technology is available to homes and offices for drinking water filtration

    Aquasky rot 4 water system is the process by which water molecules are forced through a 0.0001 micron semi-permeable membrane by water pressure. Long sheets of the membrane are ingeniously sandwiched together and rolled up around a hollow central tube in a spiral fashion. This rolled-up configuration is commonly referred to as a spiral wound membrane or module. They are available in different sizes for processing different quantities of water. Typically, a module for home water treatment is as small as 2" diameter and 10" long, while one for industrial use may be 4" diameter and 40" long.

    • AQUASKY Water containing impurities enters the system

    • Impurities are stopped and rejected at the membrane surface

    • Water pressure forces water molecules through the membrane

    • The purified water is then sent directly to the faucet

    • Impurities are expelled from the system and sent to a drain underneath the sink area.

    For the AQUASKY membrane to be usable it must be in some type of container (membrane housing) so pressure can be maintained on its surface. It is this pressure that supplies the energy to force the water through the membrane, separating it from unwanted substances. The most amazing aspect of AQUA SKY U.S.A  is that the substances left behind are automatically diverted to a waste drain so they don't build up in the system as with conventional filtering devices. This is accomplished by using a part of the unprocessed water (feed water) to carry away the rejected substances to the drain, thus keeping the membrane clean. This is the reason to why RO membranes can last so long and perform like new with minimum maintenance even after years of operation.

    • AQUASKY 5 stage reverse osmosis water systems are designed for durability and safety. We are one of the very few manufacturers who still insist on using FDA/NSF certified premium components made in the United States.

    • Our durable filter-housings can withstand extreme pH and pressure changes without leaking or bursting. Our advanced reverse osmosis membranes offer the highest contaminant removal rate, giving you the purest water possible.

    • For 25 years, AQUASKY ROT4 known as the leading manufacturer of high performance RO systems. Our systems are built to meet the most demanding applications in water purification from drinking water for homes, healthcare facilities, to research labs. Our durable RO systems last for decades, they bring years of enjoyment and good health to their users.

    AQYASKY REVERSE OSMOSIS WATER SYSTEM

     

                          Aqua sky REVERSE OSMOSIS WATER SYSTEM pushing the uncontaminated water to the other side.

    • The process involves forcing water through very fine stages  small enough to trap molecules of pollutants, but large enough to allow the water to pass. Such fine filtration means aqua sky usa water plant  is a slow process, producing just a few gallons of water at a time. In which case, the purified water is stored in a tank that is typically placed below the sink, so the system can continually work toward building up a storage of purified water to draw from

    • As pure water passes through aqua sky usa water plant  the contaminated waterblocked and  diverted through a hose connected to your drain, in order to be properly disposed of.

    • The process of aqua sky rot-4 usa water plant  requires a driving force to push the water through the membrane. The pressure provided by a standard residential water system (about 50 psi+) is typically sufficient. If your water pressure is below 50 psi (pounds per square inch), you will need a model with a booster pump.rot 4 water  ilters , tank pro water filtr , tankpro filters , tankpro water system , tankpro replacements filters , tankpro filters cartridges , under sink tankpro water filter replacements , tankpro water system under sink , tankpro 5 stage water filter , tankpro reverse osmosis , tankpro cartridges tankpro

     

     

    The heart of a Aqua Sky U.S.A plant system is, of course, its membrane. Yet not all membranes are made the same. Different manufacturers fabricate their membranes differently. For example, spiral-wound membranes are comprised of membrane "leaves" individual sheets of membrane through which feed water passes and is filtered. Some membrane brands have fewer and larger leaves. Some have more and shorter leaves. Short-leaf design costs more to fabricate, but is advantageous because less pressure is required to deliver water to the end of each leaf, and more uniform flux is maintained from one end of the leaf to the other. The result is a highly efficient membrane —one that provides safer drinking water and a longer life. For example, Aqua sky U.S.A Water treatment's' high quality water is achieved by advanced reverse osmosis membranes which have up to twice as many leaves and each leaf is 1/3 to 2/3 shorter than those in other membranes. Besides the overall system design and the quality of parts used, the membrane is the reason why different ROs have different rejection capabilities.

    This article is aimed towards an audience that has little or no experience with Reverse Osmosis and will attempt to explain the basics in simple terms that should leave the reader with a better overall understanding of Reverse Osmosis technology and its applications.

     

    What contaminants will aquasky rot-4 reverse osmosis water filter remove from water?

    aquasky Reverse Osmosis is capable of removing up to 99%+ of the dissolved salts (ions), particles, colloids, organics, bacteria and pyrogens from the feed water (although an RO system should not be relied upon to remove 100% of bacteria and viruses). An RO membrane rejects contaminants based on their size and charge. Any contaminant that has a molecular weight greater than 200 is likely rejected by a properly running RO system (for comparison a water molecule has a MW of 18). Likewise, the greater the ionic charge of the contaminant, the more likely it will be unable to pass through the RO membrane. For example, a sodium ion has only one charge (monovalent) and is not rejected by the RO membrane as well as calcium for example, which has two charges. Likewise, this is why an RO system does not remove gases such as CO2 very well because they are not highly ionized (charged) while in solution and have a very low molecular weight. Because an RO system does not remove gases, the permeate water can have a slightly lower than normal pH level depending on CO2 levels in the feed water as the CO2 is converted to carbonic acid.

    Reverse Osmosis is very effective in treating brackish, surface and ground water for both large and small flows applications. Some examples of industries that use RO water include pharmaceutical, boiler feed water, food and beverage, metal finishing and semiconductor manufacturing to name a few.

     

    Aquasky rot 4 under sink Reverse Osmosis Performance & Design Calculations

    There are a handful of calculations that are used to judge the performance of an RO system and also for design considerations. aquasky rot-4 RO system has instrumentation that displays quality, flow, pressure and sometimes other data like temperature or hours of operation. In order to accurately measure the performance of an RO system you need the following operation parameters at a minimum:

    1. Feed pressure

    2. Permeate pressure

    3. Concentrate pressure

    4. Feed conductivity

    5. Permeate conductivity

    6. Feed flow

    7. Permeate flow

    8. Temperature

     

    Salt Rejection in ( % )

    This equation tells you how effective the RO membranes are removing contaminants. It does not tell you how each individual membrane is performing, but rather how the system overall on average is performing. A well-designed RO system with properly functioning RO membranes will reject 95% to 99% of most feed water contaminants (that are of a certain size and charge). You can determine how effective the RO membranes are removing contaminants by using the following equation: 

    Understanding the difference between passes and stages in Aquasky rot 4 Reverse Osmosis (RO) system

    The terms stage and pass are often mistaken for the same thing in an RO system and can be confusing terminology for an RO operator. It is important to understand the differnce between a 1 and 2 stage RO and a 1 and 2 pass RO.

     

    Difference between a 1 and 2 stage aquasky rot -4 RO System

    In a one stage RO system, the feed water enters the RO system as one stream and exits the RO as either concentrate or permeate water. 

    In a two-stage system the concentrate (or reject) from the first stage then becomes the feed water to the second stage. The permeate water is collected from the first stage is combined with permeate water from the second stage. Additional stages increase the recovery from the system.

     

    Array

    In a Reverse Osmosis System an array describes the physical arrangement of the pressure vessels in a 2 stage system. Pressure vessels contain RO membranes (usually from 1 to 6 RO membranes are in a pressure vessel). Each stage can have a certain amount of pressure vessels with RO membranes. The reject of each stage then becomes the feed stream for the next successive stage. The 2 stage RO system displayed on the previous page is a 2:1 array which means that the concentrate (or reject) of the first 2 RO vessels is fed to the next 1 vessel.

     

    Aquasky rot 4 RO System with Concentrate Recycle

    With an RO system that can't be properly staged and the feed water chemistry allows for it, a concentrate recycle setup can be utilized where a portion of the concentrate stream is fed back to the feed water to the first stage to help increase the system recovery.

     

    Single Pass RO vs Double Pass RO

    Think of a pass as a stand alone RO system. With this in mind, the difference between a single pass RO system and a double pass RO system is that with a double pass RO, the permeate from the first pass becomes the feed water to the second pass (or second RO) which ends up producing a much higher quality permeate because it has essentially gone through two RO systems.

    Besides producing a much higher quality permeate, a double pass system also allows the opportunity to remove carbon dioxide gas from the permeate by injecting caustic between the first and second pass. C02 is undesirable when you have mixed bed ion exchange resin beds after the RO. By adding caustic after the first pass, you increase the pH of the first pass permeate water and convert C02 to bicarbonate (HCO3-) and carbonate (CO3-2) for better rejection by the RO membranes in the second pass. This can't be done with a single pass RO because injecting caustic and forming carbonate (CO3-2) in the presence of cations such as calcium will cause scaling of the RO membranes.

     

    Aqua sky Under sink Reverse Osmosis RO Pre treatment

    Proper pre treatment using both mechanical and chemical treatments is critical for an RO system to prevent fouling, scaling and costly premature RO membrane failure and frequent cleaning requirements. Below is a summary of common problems an RO system experiences due to lack of proper pretreatment.

     

    Fouling

    Fouling occurs when contaminants accumulate on the membrane surface effectively plugging the membrane. There are many contaminants in municipal feed water that are naked to the human eye and harmless for human consumption, but large enough to quickly foul (or plug) an RO system. Fouling typically occurs in the front end of an RO system and results in a higher pressure drop across the RO system and a lower permeate flow. This translates into higher operating costs and eventually the need to clean or replace the RO membranes. Fouling will take place eventually to some extent given the extremely fine pore size of an RO membrane no matter how effective your pretreatment and cleaning schedule is. However, by having proper pretreatment in place, you will minimize the need to address fouling related problems on a regular basis.

    Fouling can be caused by the following:

    1. Particulate or colloidal mater (dirt, silt, clay, etc.)

    2. Organics (humic/fulvic acids, etc)

    3. aquasky water filters and Microorganisms (bacteria, etc). Bacteria present one of the most common fouling problems since RO membranes in use today cannot tolerate a disinfectant such as chlorine and thefore microorganisms are often able to thrive and multiply on the membrane surface. They may product biofilms that cover the membrane surface and result in heavy fouling.

    4. Breakthrough of filter media upstream of the RO unit. GAC carbon beds and softener beds may develop an under drain leak and if there is not adequate post filtration in place the media can foul the RO system.

    By performing analytical tests, you can determine if the feed water to your RO has a high potential for fouling. To prevent fouling of an RO system, mechanical filtration methods are used. The most popular methods to prevent fouling are the use of multi-media filters (MMF) or microfiltration (MF). In some cases cartridge filtration will suffice.

     

    Scaling

    As certain dissolved (inorganic) compounds become more concentrated (remember discussion on concentration factor) then scaling can occur if these compounds exceed their solubility limits and precipitate on the membrane surface as scale. The results of scaling are a higher pressure drop across the system, higher salt passage (less salt rejection), low permeate flow and lower permeate water quality. An example of a common scale that tends to form on an RO membrane is calcium carbonate (CaCO3).

     

    Mechanical Damage

    Part of the pre treatment scheme should be pre and post RO system plumbing and controls. If 'hard starts' occur mechanical damage to the membranes can occur. Likewise, if there is too much back pressure on the RO system then mechanical damage to the RO membranes can also occur. These can be addressed by using variable frequency drive motors to start high pressure pumps for RO systems and by installing check valve(s) and/or pressure relief valves to prevent excessive back pressure on the RO unit that can cause permanent membrane damage.

     

    Pretreatment Solutions

    Below are some pre-treatment solutions for RO systems that can help minimize fouling, scaling and chemical attack.

     

    Multi Media Filtration (MMF)

    A Multi-Media Filter is used to help prevent fouling of an RO system. A Multi-Media Filter typically contains three layers of media consisting of anthracite coal, sand and garnet, with a supporting layer of gravel at the bottom. These are the medias of choice because of the differences in size and density. The larger (but lighter) anthracite coal will be on top and the heavier (but smaller) garnet will remain on the bottom. The filter media arrangement allows the largest dirt particles to be removed near the top of the media bed with the smaller dirt particles being retained deeper and deeper in the media. This allows the entire bed to act as a filter allowing much longer filter run times between backwash and more efficient particulate removal.

    A well-operated Multi-Media Filter can remove particulates down to 15-20 microns. A Multi-Media Filter that uses a coagulant addition (which induces tiny particles to join together to form particles large enough to be filtered) can remove particulates down to 5-10 microns. To put this in perspective, the width of a human hair is around 50 microns.

    A multi media filter is suggested when the Silt Density Index (SDI) value is greater than 3 or when the turbidity is greater than 0.2 NTU. There is no exact rule, but the above guidelines should be followed to prevent premature fouling of RO membranes.

    It is important to have a 5 micron cartridge filter placed directly after the MMF unit in the event that the under drains of the MMF fail. This will prevent the MMF media from damaging downstream pumps and fouling the RO system.

     

    Aquasky rot-4 reverse osmosis water systems are the Micro filtration (MF)

    Micro filtration (MF) is effective in removing colloidal and bacteria matter and has a pore size of only 0.1-10µm. Microfiltration is helpful in reducing the fouling potential for an RO unit. Membrane configuration can vary between manufacturers, but the "hollow fiber" type is the most commonly used. Typically, the water is pumped from the outside of the fibers, and the clean water is collected from the inside of the fibers. Microfiltration membranes used in potable water applications usually operate in "dead-end" flow. In dead-end flow, all of the water fed to the membrane is filtered through the membrane. A filter cake that must be periodically backwashed from the membrane surface forms. Recovery rates are normally greater than 90 percent on feed water sources which have fairly high quality and low turbidity feeds.

     

    Antiscalants and Scale Inhibitors

    Antiscalants and scale inhibitors, as their name suggests, are chemicals that can be added to feed water before an RO unit to help reduce the scaling potential of the feed water. Antiscalants and scale inhibitors increase the solubility limits of troublesome inorganic compounds. By increasing the solubility limits, you are able to concentrate the salts further than otherwise would be possible and therefore achieve a higher recovery rate and run at a higher concentration factor. Antiscalants and scale inhibitors work by interfering with scale formation and crystal growth. The choice of antiscalant or scale inhibitor to use and the correct dosage depends on the feed water chemistry and RO system design.

     

    Softening by ion exchange

    A water softener can be used to help prevent scaling in an RO system by exchanging scale forming ions with non scale forming ions. As with a MMF unit, it is important to have a 5 micron cartridge filter placed directly after the water softener in the event that the under drains of the softener fail.

     

    Sodium Bisulfite (SBS) injection

    By adding sodium bisulfite (SBS or SMBS), which is a reducer, to the water stream before an RO at the proper dose you can remove residual chlorine.

     

    Granular Activated Carbon (GAC)

    GAC is used for both removing organic constituents and residual disinfectants (such as chlorine and chloramines) from water. GAC media is made from coal, nutshells or wood. Activated carbon removes residual chlorine and chloramines by a chemical reaction that involves a transfer of electrons from the surface of the GAC to the residual chlorine or chloramines. The chlorine or chloramines ends up as a chloride ion that is no longer an oxidizer.

    The disadvantage of using a GAC before the RO unit is that the GAC will remove chlorine quickly at the very top of the GAC bed. This will leave the remainder of the GAC bed without any biocide to kill microorganisms. A GAC bed will absorb organics throughout the bed, which is potential food for bacteria, so eventually a GAC bed can become a breeding ground for bacteria growth which can pass easily to the RO membranes. Likewise, a GAC bed can produce very small carbon fines under some circumstances that have the potential to foul an RO.

     

    Aquasky RO Data Trending and Normalization

    The RO membranes are the heart of the RO system and certain data points need to be collected to determine the health of the RO membranes. These data points include the system pressures, flows, quality and temperature. Water temperature is directly proportional to pressure. As the water temperature decreases it becomes more viscous and the RO permeate flow will drop as it requires more pressure to push the water through the membrane. Likewise, when the water temperature increases the RO permeate flow will increase. As a result, performance data for an RO system must be normalized so that flow variations are not interpreted as abnormal when no problem exists. The normalized flows, pressures and salt rejection should be calculated, graphed and compared to the baseline data (when the RO was commissioned or after the membranes were cleaned or replaced) to help troubleshoot any problems and also determine when to clean or inspect the membranes for damage. Data normalization helps display the true performance of the RO membranes. As a general rule of thumb, when the normalized change is +/- 15% from the baseline data then you need to take action. If you don't follow this rule then RO membrane cleanings may not be very effective at bringing the membranes back to near new performance.

     

    The old models of Aquasky Water System RO Membrane Cleaning - 1950th up to 1970th

    RO membranes  in older models Aquasky water filter used to required periodic cleaning, anywhere from 1 to 4 times a year depending on the feed water quality , will that is not happening anymore  in new models we have today, As a general rule in the old models , if the normalized pressure drop or the normalized salt passage has increased by 15%, then it is time to clean the RO membranes. If the normalized permeate flow has decreased by 15% then it is also time to clean the RO membranes. You can either clean the RO membranes in place or have them removed from the RO system and cleaned off site by a service company that specializes in this service. It has been proven that offsite membrane cleaning is more effective at providing a better cleaning than onsite cleaning skids.

    RO membrane cleaning involves low and high pH cleaners to remove contaminants from the membrane. Scaling is addressed with low pH cleaners and organics, colloidal and bio fouling are treated with a high pH cleaner. Cleaning RO membranes is not only about using the appropriate chemicals. There are many other factors involved such as flows, water temperature and quality, properly designed and sized cleaning skids and many other factors that an experienced service group must address in order to properly clean RO membranes.

    with Our ro systems Today all you need to do is replacing the membrane every 4 to 5 years .

     

    Aquasky rot-4 reverse osmosis under sink water filters Summary

    Reverse Osmosis is an effective and proven technology to produce water that is suitable for many industrial applications that require demineralized or deionized water. Further post treatment after the RO system such as mixed bed deionization can increase the quality of the RO permeate and make it suitable for the most demanding applications. Proper pre treatment and monitoring of an RO system is crucial to preventing costly repairs and unscheduled maintenance. With the correct system design, maintenance program, and experienced service support, your aquasky RO water system system should provide many years of high purity water.

     

    AQUA SKY ROT 4 REVERSE OSMOSIS WATER FILTER.png
    bottom of page